Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add filters








Language
Year range
1.
Journal of Sun Yat-sen University(Medical Sciences) ; (6): 699-704, 2017.
Article in Chinese | WPRIM | ID: wpr-607267

ABSTRACT

[Objective]To evaluate the terminal hair growth of different body positions among in pregnant women ,analyze the contribution of each area to the diagnosis to hirsutism ,to improve the mFG scoring system.[Method]Pregnant women aged 20~41 years,with normal range of total testosterone levels and non-hirsute were recruited at their prenatal care in Sun Yat-sen Memorial Hospital,Sun Yat-sen University. They were followed up before pregnancy,at the 5th and the 9th week,the 10th and the 14th week, the 15th and the 20th week,the 21th and the 24th week of gestation. Then 72 more cases of pregnant women were recruited and followed up at 15~24th week. At each time of followed up,their total testosterone(TT)levels was examined by liquid chromatography tandem mass spectrometry(LC/MS-MS)and terminal hair growth were assessed by mFG score. Significant difference procedure least(LSD) analysis of variance was used to compare the levels of testosterone and mFG score in different gestational weeks. Receiver operating characteristics(ROC)analysis and logistics analysis were conducted to evaluate the contributory strength of hair growth in each body position for the diagnosis of hirsutism. The scores in the body area which made a significant contribution to the total were summed up and termed the simplified mFG score(sFG score). Following,the sFG scores were subjected to ROC analysis to determine the thresh-old that would maximize both the sensitivity and specificity of the measure to accurately distinguish hirsute from non-hirsute patients.[Results]Among the forty three pregnant women who were followed-up from before pregnancy to 24th week,the mean±SD for TT was (1.09 ± 0.59)nmol/L before pregnancy,and(1.13 ± 0.40),(1.28 ± 0.38),(1.83 ± 0.63),(1.82 ± 0.52)nmol/L for 5~ 9th,10~14th,15~20th week,and the mFG score was 1.65 ± 0.60,2.30 ± 0.45,3.60 ± 0.68,4.20 ± 0.41 and 4.40 ± 0.77,respectively. The order of the facial and body sites presented with new terminal hair growth was upper abdomen,lower abdomen,lower back,up-per lip,thighs,upper back,chest,upper arm,and chin,in sequence. After analyzing 115 cases(including the 72 cases recruited later),ROC analysis showed that the diagnostic value of different sites for hirsutism(mFG≥5):upper lip>lower back>thighs>lower abdomen>upper arm>upper back>chest/upper abdomen. Four sites among them ,namely upper lip ,lower back ,thighs and lower abdomen had the best diagnostic value,and the AUC for ROC were 0.779,0.728,0.675,and 0.626,respectively. Both ROC and logistic analysis indicated that he most significant body areas in defining hirsutism(defined as an mFG score≥5)were the upper lip, lower back,thighs,and lower abdomen. Using a cut-off value of 3,the combination of the four areas has the best sensitivity and specificity in distinguishing hirsute from non-hirsute women. [Conclusion]The study suggested that the mFG score increased as pregnancy progressed before the 24 weeks of gestation. The subset of upper lip,lower back,thighs and lower abdomen may be a reli-able simplification of mFG system for the evaluation of excess hair growth. The cut-off value was of≥3.

2.
Chinese Journal of Experimental Ophthalmology ; (12): 1097-1101, 2014.
Article in Chinese | WPRIM | ID: wpr-637429

ABSTRACT

Background It is essential to measure and assess the parameters of ocular anterior segment for refractive surgery in myopic eyes.Some different imaging devices can be used for biometric measurement of ocular anterior segment,but which is more accurate and convenient is still under investigation.Objective This study was to compare the anterior segment parameters in myopic eyes measured by anterior segment optical coherence tomography (AS-OCT),Orbscan topography and ultrasonic pachymetry (US).Methods One hundred and forty eyes of 70 myopic subjects with the diopter of-0.75 to-10.25 D,who intended to receive corneal refractive surgery in the Second Affiliated Hospital of Zhejiang University School of Medicine from November 2011 to May 2012,were retrospectively analyzed.Central corneal thickness (CCT) was measured using AS-OCT,Orbscan Ⅱ and US,respectively,and anterior chamber depth (ACD) was measured by AS-OCT and Orbscan Ⅱ,and the angle to angle (ATA) distance and corneal white-to-white corneal distance (WTW) were measured by AS-OCT and Orbscan Ⅱ,respectively.The parameters from different apparatuses were statistically compared.Results The mean CCT were (516.57±30.25) μm in AS-OCT,(523.68±31.87) μm in US and (514.69±38.40) μm in Orbscan Ⅱ,without significant difference among them (F =2.775,P =0.063).Then the patients were divided into three groups based on the US measurement of CCT (<500 μm group,500-569 μm group,and ≥ 570 μm group).In the <500 μm group,there was a significant difference in the CCT among the three methods (F =22.236,P =0.000),significant differences were found between AS-OCT and Orbscan Ⅱ,or Orbscan Ⅱ and US(both at P<0.05).In the 500-569 μm group,there was no significant difference in the CCT among the three methods (F =3.011,P =0.051).In the ≥ 570 μm group,there was a significant difference in the CCT among the three methods (F =4.133,P =0.021),a significant difference was found between AS-OCT and US(P<0.05),but there was no significant difference between AS-OCT and Orbscan Ⅱ (P>0.05).The ACD values measured by AS-OCT was (3.83±0.21) mm,which was higher than (3.75 ± 0.21) mm by Orbscan Ⅱ,with a significant difference between them (t =-8.520,P =0.000).In addition,the ATA value by AS-OCT (12.43 mm±0.74 mm) was higher than the WTW value (11.42 mm±0.33 mm) by OrbscanⅡ,with a significant difference between them(t=-18.088,P=0.000).Conclusions AS-OCT,US and Orbscan Ⅱ can offer accurate CCT value,and they can provide references to one another before refractive surgery.However,the ACD,ATA and WTW values by AS-OCT and Orbscan]Ⅱ have large differences.

3.
Chinese Journal of Dermatology ; (12): 544-547, 2011.
Article in Chinese | WPRIM | ID: wpr-416999

ABSTRACT

Objective To evaluate the performance of nested PCR in the detection of different fungi in paraffin wax embedded tissues. Methods Forty-four tissue samples were resected from rats infected with Fonsecaea monophora, patients with chromoblastomycosis, sporotrichosis or penicilliposis marneffei followed by preparation of paraffin wax embedded tissue sections for pathological examination and DNA extraction. Nested PCR was performed by using specific primers targeting the ribosomal DNA of Fonsecaea, Sporothrix and Penicillium marneffei, respectively. The sensitivity and specificity of nested PCR were analyzed and compared with those of pathological examination. Results The nested PCR showed positive results in 8 of 20 samples from rats with chromoblastomycosis, 7 of 10 samples from patients with sporotrichosis and all of the 10 samples from patients with penicilliposis marneffei, but not in the control samples. In the detection of Fonsecaea,Sporothrix schenki and Penicillium marneffei, the sensitivity was 40% ,70% and 100%, respectively, and the specificity was consistently 100%, for the nested PCR. Pathological examination revealed fungal elements in 95%, 70% and 80% of the corresponding samples, respectively. Conclusion Detection of fungal DNA in paraffin wax embedded tissue by nested PCR can be applied to the diagnosis of deep mycosis, especially to the diagnosis of penicilliposis marneffei.

4.
Journal of Biomedical Engineering ; (6): 496-498, 2006.
Article in Chinese | WPRIM | ID: wpr-249569

ABSTRACT

The signal analysis technology based on wavelet was used to detect the chromatic visual evoked potential (VEP). The method was based on wavelet transform modulus maxima reconstruction. The test signal was decomposed using the dyadic discrete time wavelet transform "Mallat" algorithm, and the modulus maxima distribution of each scale was obtained. Signal was de-noised as the Lipschitz coefficient. The POCS method was used to reconstruction the original signal. The news method proved not only good for de-noising but also for decreasing the times of test by the simulation result.


Subject(s)
Humans , Color , Electrocardiography , Methods , Evoked Potentials, Visual , Signal Processing, Computer-Assisted
SELECTION OF CITATIONS
SEARCH DETAIL